Thermal
Properties of Hydrogen, H2 (Gaseous) |
|
|
|
Molecular
Weight, 2.016 |
|
|
Normal
Boiling Point 20.268 K |
Triple Pt. Temp, 13.81K |
Critical Point, 32.98 K |
|
|
T (K) |
Density |
|
Heat
Capacity |
Thermal Conductivity |
Viscosity |
|
Prandtl Number |
|
(g/cc) |
|
(J/gK) |
|
(W/cmK) |
|
(g/cm sec) |
|
Pr |
|
2000 |
1.23E-05 |
|
18.180 |
|
8.92E-03 |
|
3.26E-04 |
|
0.67 |
|
1500 |
1.60E-05 |
|
16.050 |
|
6.22E-03 |
|
2.68E-04 |
|
0.69 |
|
1000 |
2.46E-05 |
|
14.980 |
|
4.45E-03 |
|
2.03E-04 |
|
0.68 |
|
800 |
3.07E-05 |
|
14.700 |
|
3.75E-03 |
|
1.74E-04 |
|
0.68 |
|
600 |
4.09E-05 |
|
14.550 |
|
3.05E-03 |
|
1.43E-04 |
|
0.68 |
|
500 |
4.91E-05 |
|
14.520 |
|
2.69E-03 |
|
1.27E-04 |
|
0.68 |
|
400 |
6.14E-05 |
|
14.550 |
|
2.31E-03 |
|
1.09E-04 |
|
0.68 |
|
300 |
8.18E-05 |
|
14.850 |
|
1.94E-03 |
|
8.95E-05 |
|
0.69 |
|
250 |
9.80E-05 |
|
15.330 |
|
1.76E-03 |
|
7.90E-05 |
|
0.69 |
|
200 |
1.23E-04 |
|
16.080 |
|
1.57E-03 |
|
6.78E-05 |
|
0.70 |
|
150 |
1.64E-04 |
|
16.160 |
|
1.29E-03 |
|
5.56E-05 |
|
0.70 |
|
100 |
2.46E-04 |
|
13.400 |
|
8.01E-04 |
|
4.21E-05 |
|
0.70 |
|
80 |
3.08E-04 |
|
11.770 |
|
6.03E-04 |
|
3.59E-05 |
|
0.70 |
|
60 |
4.11E-04 |
|
10.740 |
|
4.47E-04 |
|
2.90E-05 |
|
0.70 |
|
40 |
6.24E-04 |
|
10.580 |
|
3.09E-04 |
|
2.08E-05 |
|
0.71 |
|
30 |
8.47E-04 |
|
10.830 |
|
2.40E-04 |
|
1.62E-05 |
|
0.73 |
|
25 |
1.04E-03 |
|
11.170 |
|
2.02E-04 |
|
1.37E-05 |
|
0.76 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
T(K) = Temperature in Kelvin, T(C) =
Temperature in Celsius |
|
|
T (C) =
T (K) - 273 |
|
|
|
Heat Capacity [=] 1 J/gK = 0.23864
BTU/lbm/F |
|
|
|
Thermal Conductivity [=] 1 W/cmK =
57.77 BTU/hr/ft/F |
|
|
|
Viscosity [=] 1 g/cm sec = 1 poise =
241.9 lbm/ft/hr |
|
|
|
Back to Property Main Page |
|
Do You Know Someone Who Needs A Job in Engineering, Physics or Chemistry?
|
Note:
The material of this page is copyrighted.
No part of this page shall be copied, stored or reproduced without
written permission. |
|
Disclaimer:
The information of this page is provided to our best knowledge. However we are not responsible for any
potential errors in the data. |
|
|
|
|
|
|
|
|
|
|
|